Pepperl+Fuchs® KFD2-UFC-1.D

Pepperl+Fuchs® KFD2-UFC-1.D Logic Control Unit Universal Frequency Converter With Trip Values, 22/18 VAC Input, 250 VAC/40 VDC Output, 2/2.2 W, Digital Input

  • MPN: KFD2-UFC-1.D
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Pepperl+Fuchs® KFD2-UFC-1.D

The frequency converter converts an input frequency into a frequency proportional current and offers at the same time the possibility to monitor trip values. The frequency value for the minimum (0 mA or 4 mA) and the maximum output current (20 mA) is freely parameterisable. Also the functions of the switch outputs (2 relay outputs and 1 potential free transistor output) are freely adjustable [trip value display (Min/Max alarm), serially switched output, pulse divider output, error signal output]. A start-up override that can be activated externally is integrated as well. The maximum input frequency is 12 kHz. The input and output circuits are galvanically isolated. The frequency converter can be supplied via the Power Rail, which also transfers the collective error message. The device can be adjusted by means of the control panel or the software.

Pepperl+Fuchs® Universal Frequency Converter, Logic Control Unit, Digital Input, 22/18 VAC Input, 250 VAC/40 VDC Output, 40/5 mA Input Current, 2 A/20 mA Output, 2/2.2 W, Terminal, DIN Rail Mount, -20 to 60 deg C, 200 ms Response, 0.001 Accuracy, 250 VAC/2 A/40 VDC at 2 A Contact Loading, 1.6 in L x 3.9 in W x 4.5 in H

Accuracy      :      0.001
Connection Type      :      Terminal
Dimensions      :      1.6 in L x 3.9 in W x 4.5 in H
Input Current      :      40/5 mA
Mounting Type      :      DIN Rail
Output Current      :      2 A/20 mA
Response Time      :      200 ms
Specifications      :      250 VAC/2 A/40 VDC at 2 A Contact Loading
Temperature Rating      :      -20 to 60 deg C
Type      :      Logic Control Unit
Input Voltage      :      22/18 VAC
Output Voltage      :      250 VAC/40 VDC
Power Rating      :      2/2.2 W
Input Type      :      Digital
  • 1-channel signal conditioner
  • 24 VDC supply (power rail)
  • Input for 2 or 3 wire sensors, NAMUR sensors or dry contacts
  • Input frequency 1 MHz to 12 kHz
  • Current output 0/4 to 20 mA
  • Relay and transistor output
  • Start-up override
  • Line fault detection (LFD)
  • IP20 protection degree
  • pdfSpecification Sheet https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/PepperlFuchs_KFD2_UFC_1D_Specification_Sheet.pdf