Non Stock
printPrint
  1. pin-int

Crouse-Hinds EBMBA WT15EHD34

EATON Crouse-Hinds EBMBA WT15EHD34 Dust-Ignitionproof Explosionproof Raintight Circuit Breaker, 480 VAC/250 VDC, 15 A, 18 kA Interrupt, 3 Poles

  • MPN: EBMBA WT15EHD34
  • UPC: 782274598628
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Crouse-Hinds EBMBA WT15EHD34

EATON Crouse-Hinds Circuit Breaker, Dust-Ignitionproof Explosionproof Raintight, Series: EBMBA, 480 VAC/250 VDC, 15 A, 18 kA Interrupt, EHD Frame, 15 A Trip, 3 Poles, 19.4 in H x 14.78 in W x 10.25 in D, Copper-Free Aluminum

Dimensions      :      19.4 in H x 14.78 in W x 10.25 in D
Frame      :      EHD
Material      :      Copper-Free Aluminum
Series      :      EBMBA
Trip Range      :      15 A
Type      :      Dust-Ignitionproof Explosionproof Raintight
Voltage Rating      :      480 VAC/250 VDC
Amperage Rating      :      15 A
Interrupt Rating      :      18 kA
Number of Poles      :      3
  • Rugged, corrosion-resistant
  • Circuit breaker operating handle located through the right side wall of the body permits visual confirmation of correct component assembly and operation
  • Total compliance to the wiring end room requirements of the National electrical Code®
  • Semi clamshell enclosure design, with an external flanged ground joint between body and cover makes interior components more accessible
  • Minimum enclosure to enclosure spacing with little interference between the opened cover and an adjacent enclosure
  • Copper-free aluminum hinges allow the cover to swing well out of the way
  • Stainless steel, quick release, captive, hex head cover bolts
  • Stainless steel springs provide clear indication cover bolts are fully retracted from body
  • Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufacturers breakers
  • Simple, straight forward installation of breaker on pre-drilled mounting plate within enclosure, mounting plate also field removable
  • Circuit breaker external operating handle can be padlocked in either ON or OFF positions
  • Neoprene cover gasket permanently attached to the cover seals out moisture
  • Bodies have top and bottom drilled and tapped entrances for power conduits and control conduits
  • Removable reducers are supplied, as standard, to accommodate smaller size conduits, all conduit entrances are plugged
  • Tap on mounting feet
  • 18 kA at 240 VAC interrupt rating
  • pdfCatalog https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_fb8ad342feacf863fce43dad4f4d19f1a1a44cd47f5b6a9a262d9ae3a60506f5.pdf
  • pdfSpecification Sheet https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_ecec1b2895f7bb1d84002f88bdc1d03fb1e6a030e9627f5d112259bad26196c2.pdf