REES Cable Operated Switch, Heavy Duty Manual Reset Slack, 600 VAC, 250 VDC, Positive Break Action, NC-NO Contact Configuration, 6 A at 110 to 120 VAC, 3 A at 220 to 240 VAC, 1.5 A at 440 to 480 VAC, 1.2 A at 550 to 600 VAC, 2.2 A at 115 to 125 VDC, 1.1 A at 230 to 250 VDC Contact, T-Handle Actuator, NEMA 4X/IP66 Enclosure, Conduit/Surface Mounting, 14 AWG Stranded Wire Terminal, 0 to 55 deg C, Aluminum, 3.9 in H Dimensions
| Action |
: |
Positive Break |
| Actuator |
: |
T-Handle |
| Contact Rating |
: |
6 A at 110 to 120 VAC, 3 A at 220 to 240 VAC, 1.5 A at 440 to 480 VAC, 1.2 A at 550 to 600 VAC, 2.2 A at 115 to 125 VDC, 1.1 A at 230 to 250 VDC |
| Dimensions |
: |
3.9 in H |
| Enclosure Type |
: |
NEMA 4X/IP66 |
| Material |
: |
Aluminum |
| Mounting Type |
: |
Conduit/Surface |
| Temperature Rating |
: |
0 to 55 deg C |
| Terminal Type |
: |
14 AWG Stranded Wire |
| Type |
: |
Heavy Duty Manual Reset Slack |
| Voltage Rating |
: |
600 VAC, 250 VDC |
| Contact Configuration |
: |
NC-NO |
- This switch is particularly competent for use in emergency stop applications as well as for ordinary circuit control
- The housing is made from high quality die cast aluminum and painted with a white powder coating that has no residual heavy metals and contains no lead or reactive materials that may be considered unsafe in food
- Manual reset with positive break contacts
- Gold plated contacts eliminate high resistance tarnishing
- May be mounted for right or left hand pull
- Each switch is supplied with a fibreflex gasket which provides an oil tight seal upon installation
- For added protection against corrosive environments a neoprene gasket is available as an accessory item by ordering part number 02005-540
- There are two 1/2 in NPT conduit openings
- The maximum cable recommended cable length is 200 ft with a maximum interval support of 10 ft
- The mechanical life of the switch is 150000 operations
- This switch can be installed on various conveyor installations, particularly those requiring constant starting and stopping operations
- The rugged construction and long term reliability makes this cable pull switch well suited to function within various environments
- A600/N300 heavy duty rating
- -40 to 85 deg C storage temperature
- Operating temperatures at 0 deg C are based on the absence of freezing moisture and liquids
- 60, 30, 15, 12 A inrush current, 15 lb trip force, 3 lb operating force between 10 ft supports
- Slack cable style, 6 A/1.2 A at 110 to 120/550 to 600 VAC, 2.2 A/1.1 A at 115 to 125/230 to 250 VDC
-
Catalog
https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_ea21e8b71e881e5a746ad9fd0327a5ebf7eeb63fb63b838078a6a39bda09de89.pdf