Non Stock
printPrint
  1. pin-int

Rex SC7HK

Rex SC7HK Encapsulated Control Transformer, 480 VAC Primary, 120/240 VAC Secondary, 7.5 kVA Power Rating, 60 Hz, 1 Phase

  • MPN: SC7HK
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Rex SC7HK

Industrial control transformers are used to convert the available supply voltage to the voltage that is required to supply industrial control circuits and motor control loads. these loads consist of a combination of electromagnetic devices such as solenoid operated valves, switches, bells, alarms, and other components such as indicator lights, timers, electronic equipment, and logic boards. some components of a circuit, especially electromagnetic devices require a very high level of power at start up. this start up power requirement is called inrush VA. after their initial start up these components settle down to a lower power requirement for normal continuous operation. this lower operating power requirement is called sealed or steady state VA. some devices can draw up to 10 times the normal operating or sealed current for periods of up to 50 milliseconds upon start up. most devices have a minimum voltage requirement for normal operation at both start up and steady state conditions. control transformers must be designed, constructed, and selected to ensure that they provide the output voltage stability needed for trouble free operation of all circuit components. Rex control transformers incorporate several features to optimize output voltage stability and regulation when supplying industrial control circuits with high inrush current requirements. to ensure that the selected control transformer is sized adequately and suitable for the application, the following 6 step selection guidance should be followed.

Rex Control Transformer, Encapsulated, 480 VAC Primary, 120/240 VAC Secondary, 7.5 kVA Power, 60 Hz Frequency, 1 ph, 2 Taps, Lug Connection, Surface Mounting, 200 deg C Insulation, NEMA 3R/4 Enclosure, 150 deg C, Steel Housing Material, 15 in H x 13 in W x 12 in D Dimensions

Connection Type      :      Lug
Dimensions      :      15 in H x 13 in W x 12 in D
Enclosure Type      :      NEMA 3R/4
Housing Material      :      Steel
Insulation      :      200 deg C
Mounting Type      :      Surface
Number of Taps      :      2
Temperature Rating      :      150 deg C
Type      :      Encapsulated
Primary Voltage      :      480 VAC
Secondary Voltage      :      120/240 VAC
Power Rating      :      7.5 kVA
Frequency Rating      :      60 Hz
Phase      :      1
  • Mixture of silica sand resin forming a solid mass completely encloses and protects the core and coil, also significantly reduces audible noise
  • Windings utilize class 220 deg C insulating rated for 150 deg C rise, but designed to operate at 115 deg C maximum
  • The transformer's core is solidly grounded
  • Enclosure constructed from heavy gauge steel, coated with ASA 61 grey powder paint
  • Suitable for NEMA/CSA type 3R and type 4 enclosure applications for both indoor and outdoor
  • Spacious wiring compartment, cool and easily accessible (bottom or front access may depend on size)
  • Standard primary taps
  • Copper conductor
  • Dry Tape, encapsulated