3M™ 5300 Series Motor Lead Pigtail Splice Kit is perfect to use with copper compression, 1-hole lugs. It is designed to splice motor lead cables to incoming feeder cables, including the accommodation of pigtail (stub) connections at 1000 VAC or less. The kit can make 3 splices and can be used on cables that can withstand a maximum temperature of 194 deg F (90 deg C).
3M™ Motor Lead Splice Kit, 3-Cable, Series: 5300, 0 to 1000 VAC, Shielded/Lead Pigtail Cable, 250 to 500 kcmil, 4/0 AWG to 500 kcmil Conductor, 0.67 to 1.05 in OD in, 6.7 in, 1 Conductors, Pigtail Connector, 90 to 130 deg C, EPDM Rubber, Black
| Cable Type |
: |
Shielded/Lead Pigtail |
| Color |
: |
Black |
| Connector Type |
: |
Pigtail |
| Insulation Size |
: |
0.67 to 1.05 in OD in |
| Number of Conductors |
: |
1 |
| Series |
: |
5300 |
| Temperature Rating |
: |
90 to 130 deg C |
| Type |
: |
3-Cable |
| Voltage Rating |
: |
0 to 1000 VAC |
| Conductor Size |
: |
250 to 500 kcmil, 4/0 AWG to 500 kcmil |
| Splice Length |
: |
6.7 in |
| Material |
: |
EPDM Rubber |
- Fast and simple installation
- No torches or heat source required
- No special tools required to install splice
- Thick walls to resist puncture and abrasion damage
- High dielectric constant stress control included with 5/8 kV kits for shielded feeder cables for minimizing size and electrical stress
- Easy re-entry, can be used on cables with a rated operating temperature of 90 deg C and an emergency overload rating of 130 deg C, to splice (insulate and seal) motor lead connections for 1000 VAC and less cables sized 16 AWG to 500 kcmil
- 5/8 kv shielded and non-shielded feeder cables sized 8 AWG to 500 KCMIL, polyethylene cable, cross linked polyethylene cable (xlp), ethylene propylene rubber cable (epr), copper conductors
- 1-1/2 in maximum bolt length
- 1.7 in ID lug cover
- 6.7 in lug cover length
- 1400 psi tensile strength
- 750% elongation
- 365 V/mil dielectric strength
- 1/case
- 250 kcmil to 500 kcmil feeder cable, 4/0 AWG to 500 kcmil motor lead conductor size
-
Instruction/Installation Manual
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_393c588ae7421fe89854517d150e075487058cc6c365e7a97b023bcc04dfa21e.pdf
-
Line Drawing
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_dfd79800ae6ad1e2065d718daed91d06bd0bae99754de82e6ce0796bf1ab6272.pdf
-
SDS
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_81f9dba8aeffb3cd68b5c1daead8c056902f14d6321db2de323fd5bad0ed35c7.pdf
-
SDS
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_8b6fa009fb1912e54572ee2ac86fa2408fb00f7fe1dfa3b78bc4607a1dafb914.pdf
-
Specification Sheet
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_75b5d7bbb1e5a096f923d6215e9c618a2db5ec7de2c65bde4c87b1e57aed3eeb.pdf