The SmartlockPro® dual function AFCI/GFCI receptacle offers protection both from electrical fires that could result from arc-faults and from electrical shock due to ground faults in one smart device. Through advanced technology, the SmartlockPro® dual function AFCI/GFCI receptacle helps protect home and family by working to detect arc-fault and ground fault hazards and, if detected, quickly cuts off power to help avoid a potential fire or shock occurrence. The SmartlockPro® dual function AFCI/GFCI receptacle offers a National Electrical Code (NEC) compliant option for AFCI/GFCI protection in residential kitchens and laundry areas for new construction, modifications/extensions and replacement receptacles. It is also ideal as a replacement for ungrounded receptacles, satisfying for both AFCI and GFCI protection.
Leviton® Decora® Blank Face AFCI/GFCI Receptacle, Dual Function Feed-Through Monochromatic Self-Test, 125 VAC, 20 A, 1 hp, 2 Poles, 3 Wires, NEMA 5-15R/5-20R, Professional Grade, -35 to 66 deg C, Back/Side Wired Terminal, Polycarbonate, White, 4.19 in H x 1.73 in W x 1.29 in D
| Dimensions |
: |
4.19 in H x 1.73 in W x 1.29 in D |
| Grade |
: |
Professional |
| Horsepower |
: |
1 hp |
| Material |
: |
Polycarbonate |
| NEMA Rating |
: |
NEMA 5-15R/5-20R |
| Temperature Rating |
: |
-35 to 66 deg C |
| Terminal Type |
: |
Back/Side Wired |
| Type |
: |
Dual Function Feed-Through Monochromatic Self-Test |
| Voltage Rating |
: |
125 VAC |
| Amperage Rating |
: |
20 A |
| Number of Poles |
: |
2 |
| Number of Wires |
: |
3 |
| Color |
: |
White |
- May be used for outlet branch circuits where AFCI protection is desired but is located where an outlet is not needed
- Ideal for installing in locations to make AFCI protection readily accessible per NEC® requirements
- May be used on circuits feeding lighting loads as well as other loads such as smoke detectors where a receptacle is not used
- Trip threshold meets or exceeds UL requirements for tripping time on ground faults and on both series and parallel arcs for optimal safety
- On initial power up, tests the GFCI circuit within 3 s
- Patented lockout action prevents reset if the device is damaged
- Status indicator light provides simple, intuitive feedback on power and protection status as well as indication of line/load reversal
- TEST and RESET buttons are readily accessible on the face of the device
- Improved immunity to high frequency noise reduces nuisance tripping
- Superior resistance to electrical surges and over voltages enhancing reliability
- Patented bridge contact design provides individual sets of contacts for receptacle face and downstream receptacles; no power will be delivered to receptacle face if improperly wired
- 1-piece T-design trip latch mechanism provides efficient operation
- Impact-resistant thermoplastic cover and body for durability
- Expanded wiring options with nine back-wire holes (two for each line and load connection plus one for ground with an internal clamp) for easy installation
-
Instruction/Installation Manual
https://assets.unilogcorp.com/2/ITEM/DOC/Leviton_AGRBF_E_Manual.pdf
-
SDS
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_97b58a9ad322aae2b4d25b030708ccd88880ca6acc113042168afacc424cf8a2.pdf
-
Specification Sheet
https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_0a5b26ab45f235d842b4dda1072bae3c11caa3c4e7f05b7a5a9e7e57ac9fb6c5.pdf
-
Technical Bulletin
https://assets.unilogcorp.com/2/ITEM/DOC/Leviton_AGRBF_E_Technical_Bulletin.pdf