Non Stock
printPrint
  1. pin-int

ProSoft Technology 5102-MCM4-DFCM4

ProSoft Technology 5102-MCM4-DFCM4 Modbus Master/Slave To DF1 Master/slave Gateway, MCM/DF1 Protocol, 50/60 Hz, RS232/422/485 Interface

  • MPN: 5102-MCM4-DFCM4
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
ProSoft Technology 5102-MCM4-DFCM4

The ProLinx modbus master/slave to DF1 master/slave gateway creates a powerful connection between modbus master/slave and DF1 master/slave networks and devices. This stand-alone DIN rail mounted protocol gateway provides four serial ports, each individually configurable as a modbus or DF1 master or Slave. The modbus protocol driver supports master and slave implementations of the protocol. All modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering and many other instruments.

ProSoft Technology Modbus Master/Slave To DF1 Master/slave Gateway, MCM/DF1 Protocol, 50/60 Hz, RS232/422/485 Interface Type, 110 to 115 kbps Data Transfer Rate, Serial Port, 4 Ports, 5.2 in H x 2.07 in W x 4.52 in D, Environmental Conditions: 5 to 95% Humidity

Data Transfer Rate      :      110 to 115 kbps
Dimensions      :      5.2 in H x 2.07 in W x 4.52 in D
Environmental Conditions      :      5 to 95% Humidity
Number of Ports      :      4
Port Type      :      Serial
Protocol      :      MCM/DF1
Frequency Rating      :      50/60 Hz
Interface      :      RS232/422/485
  • 18 to 32 VDC allowed positive, negative, GND terminals 2.5 mm screwdriver blade power supply
  • -4 to 122 deg F operating temperature
  • Power and module status, application status, serial port activity, serial port error status LED indicators
  • DB-9M RS-232 only no hardware handshaking configuration serial port
  • 10 base-T half duplex RJ45 connector link and activity LED indicators electrical isolation 1500 Vrms at 50 Hz to 60 Hz for 60 sec EtherNet port
  • EtherNet broadcast storm resiliency is equal to less than or equal to 5000 [ARP] frames/sec and less than or equal to 5 min duration
  • Modbus plus connector two DB9 female standard modbus plus connectors are application ports
  • 2500 Vrms port signal isolation per UL 1577, 3000 VDC minimum port to ground and port to logic power isolation serial port isolation
  • 500 mA maximum at 32 VDC power supply