Abb AF09-40-00-14L

ABB AF09-40-00-14L Lighting Contactor, 250 to 500 VAC/VDC V Coil, 20 A, 4NO Contact, 4 Poles

  • MPN: AF09-40-00-14L
  • UPC: 888614010109
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Abb AF09-40-00-14L

AF09 contactors are used for controlling power circuits up to 690 VAC and 220 VDC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF contactors include an electronic coil interface accepting a wide control voltage Uc min to Uc max. Only four coils cover control voltages between 24 to 500 VAC 50/60 Hz or 20 to 500 VDC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. Mirror contacts compliant with Annex F of IEC 60947-4-1), control circuit: AC or DC operated - Accessories: a wide range of accessories is available.

ABB Lighting Contactor, 250 to 500 VAC/VDC Coil, 20 A Maximum Load Current, 2.2 kW, 4 kW, 5.5 kW, 4 kW Coil, 4 Pole, 50/60 Hz Frequency, 4NO Contact Configuration, 600 VAC Contact, AF09 Size, Screw Clamp Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 77 mm L x 45 mm W x 86 mm H Dimensions

Coil Power Rating      :      2.2 kW, 4 kW, 5.5 kW, 4 kW
Contact Rating      :      600 VAC
Dimensions      :      77 mm L x 45 mm W x 86 mm H
Enclosure Type      :      IP20
Frequency Rating      :      50/60 Hz
Operating Cycles      :      10000000 Cycles
Operating Temperature      :      -40 to 70 deg C
Size      :      AF09
Terminal Type      :      Screw Clamp
Coil Voltage      :      250 to 500 VAC/VDC
Maximum Load Current      :      20 A
Contact Configuration      :      4NO
Number of Poles      :      4
  • Built-in surge suppression
  • 2.2 kW at 220 to 240 VAC, 4 kW at 380 to 440 VAC, 5.5 kW at 500 to 690 VAC 3-phase rated operational power
  • pdfCatalog https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_AF45_40_00_70_Catalog.pdf
  • pdfFull Engineering Drawing https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_AF09_30_01_14L_Full_Engineering_Drawing.pdf
  • pdfInstruction/Installation Manual https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_AF26_40_00_11_Manual.pdf
  • pdfRoHS https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_AF38_30_00_11_RoHS.pdf
  • pdfSpecification Sheet https://uat.south.electrozad.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_AF09_40_00_14L_Specification_Sheet.pdf